Thermal Abuse Test Chamber Standards

  • IEC 62133
  • IEC 62619
  • UL 1642

 

Relevant standards requirement

Single storage cell Safety Test

Heating test steps:

  • Charge the battery according to the standard 6.1.3
  • Place it into the chamber

–For lithium storage battery, the oven temperature is raised at a rate of 5℃/min to the temperature of 130℃±2℃, remain this temperature for 30min, then stop heating.

–For metal cyanide nickel battery, the oven temperature is raised at a rate of 5℃/min to a temperature of 85℃±2℃, remain this temperature for 2h, then stop heating.

  • Observe for 1h

 

Storage Battery Module Safety Test

  • Charge the battery module according to the standard 6.1.4
  • Place it into the chamber

-For lithium storage battery, the oven temperature is raised at a rate of 5℃/min to a temperature of 130℃±2℃, remain this temperature for 30min, then stop heating.

–For metal cyanide nickel battery, the oven temperature is raised at a rate of 5℃/min to a temperature of 85℃±2℃, remain this temperature for 2h, then stop heating.

  • Observe for 1h

 

Thermal Abuse Test Chamber Technical Parameters

ModelBE-101-1000A
Temp. RangeAmbient – 200℃ (Controllable)
Control Accuracy±0.5℃
Temp. Uniformity±2.0℃( No load)
Temp. Rising SpeedRT – 150℃ (≧5℃/min, liner with load 40kg module)
Temp. overshoot≦2.0℃
Control Display MethodPLC Touch screen + remote control, networking,
Cell phone APP alarm device, with USB interface, R485 interface can be connected to computer control.
Testing Room DimensionW1000 X D1000 X H1000 mm
External Chamber DimensionW1400 X D1300 X H1840 mm
Inner chamber MaterialSUS304 Stainless Steel (Mirror finished)
External chamber MaterialSECC Steel Plate, Powder Painted
BasementWith universal wheel
Observation Window390 X 360mm (20mm Tempered Explosion Proof Glass)
Power Source380V 50HZ
Heating PowerAbout 12 KW
Safety Protection Deviceover-voltage, over-temperature, over-current protection.
protection for short circuits caused by incorrect operation of the operator and battery electrode, battery positive and negative connection, etc.
Safety DeviceSmoke exhaust system, explosion-proof pressure relief port, tri-color light alarm.

 