Traction Battery Short Circuit Test Machine

Share:

Battery Short Circuit Test Machine Relevant standard requirement

Single Storage Cell Safety Test

6.2.4 Short circuit

  1. Charge the single storage cell according to 6.1.3 standard
  2. The cell is to be short-circuited by connecting the positive and negative terminal with an external resistance of less than 5mΩ for 10 min
  3. Observe for 1H

 

Battery module safety test

6.3.4 Short circuit

  1. Charge the battery module according to standard 6.1.4
  2. The battery module is to be short-circuited by connecting the positive and negative terminal with an external resistance of less than 5mΩfor 10 min
  3. Observe for 1H

 

Standard

  • UL 2580

 

Technical Parameters

ModelBE-XL-2000ABE-XL-3000ABE-XL-5000A
Max. Operating Current(A)2000A3000A5000A
Max. Instantaneous Current(A)3000A4000A6000A
Temp. RangeAmbient Temperature
Inner Resistance<1mΩ,<5mΩ,<10mΩ,<20mΩ,<50mΩ,<100mΩ(Optional)
Control ModePLC Touch Screen + Computer remote control + Remote controller
Overall DimensionW700xD1050xH1830mm
Explosion proof Chamber Dimension800 X 800 X 800mm,1000 X 1000 X 1000mm (Optional)
Voltage Measurement Range0~500V
Short Circuit Response Time≦20ms
Data InterfaceUSB, Data card, etc.
Data Acquisition ModuleIndependent remote acquisition, multi-voltage/temperature/current acquisition channels ensure data accuracy. Acquisition frequency 100HZ
Short Circuit ModePneumatic + vacuum arc extinguishing
Safety DeviceElectric leakage, over current protection ,smoke alarm device, abnormal sound light alarm.
Testing FixtureCustomize according to actual testing condition
Power Supply220V 50HZ
en_USEnglish